Blauberg Turbo EC 100 eco

Inline mixed-flow fans
  • Impeller type: Mixed-flow
  • Casing material: Plastic
  • Installation in any position
Unit of measurement Turbo EC 100 eco
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Weight kg 1.45
Transported air temperature (max) °С 55
Transported air temperature (min) °С -25
Ingress protection rating - IPX4
Ingress protection rating of the drive - IPX4
Impeller material - Plastic
Blauberg Turbo EC 100 eco 56 187 2016
Trademark Blauberg
Model Turbo EC 100 eco
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-49.5 A+ -24.4 C -10.1 E
Type of ventilation unit Unidirectional
Type of drive installed Variable speed
Type of heat recovery system None
Maximum flow rate (m³/h) 187
Electric power input (W) 33
Reference flow rate (m³/s) 0.036
Specific power input (SPI) (W/(m³/h)) 0.123
Control typology Local demand control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 56
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
72 72 72
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5131 2623 1186
Datasheet
Turbo EC eco - data sheet
653 Kb
Manual
Turbo EC eco - user's manual (B10-2EN-01)
888 Kb
Image
Turbo EC 100 eco - image 1
482 Kb
∅ D B H L
96 167 190 246
Name Photo Description
Blauberg WKH 100-2 WKH 100-2 Duct water heaters for round ducts
Blauberg WKH 100-4 WKH 100-4 Duct water heaters for round ducts